Used Bruker NMR equipment currently on offer
|
Consoles
- Avance2plus console, 200-400 MHz: 2-4 channel console, gradient amplifier, diverse amplifiers available (up to kW)
Liquids NMR Probes
- 500 MHz BBO X{1H} double resonance, no PFG
- 300 MHz CH 13C{1H} double resonance, no PFG
Solids NMR Probes
- 500 MHz HP WB 73 15N-31P{19F-1H} double resonance MAS 4 BL CP BB DVT
Sample Changers
- BACS60 (60 samples) autosampler
Amplifiers
- BLARH1-10
200-600 MHz | 10 W (1H)
| - BLAXH50
200-400 MHz | 100 W (X) + 50 W (1H)
| - BLARH100
750-850 MHz | 100 W
| - BLA2BB board
20-400 MHz | 150 W (X) + 60 W (1H)
| - BLARH100
200-600 MHz | 100 W (1H)
| - BLARH100RS
500-600 MHz | 100 W (1H)
| - BLAX300RS
6-242 MHz | 300 W (X)
| - BLAX300RS
6-325 MHz | 300 W (X)
| - BLAX300
6-365 MHz | 300 W (X)
| - BLAX300 board
6-243 MHz | 300 W (X)
| - BLAXH300/100
200-600 MHz | 300 W (X) + 100 W (1H)
| - BLAX500
6-365 MHz | 500 W (X)
| - BLAH1000
200-600 MHz | 1000 W (1H)
| - BLAX1000
30-325 MHz | 1000 W (X)
| - BLA1000-I
15-400 MHz | 1000 W (X)
| - BLPPA20010
185-200 MHz | 2000 W
| | | | | | | | | | | | | | | | |
Air Chillers
- FTS-80 preconditioning unit: -80...+100 deg. C air chiller/heater (min. sample temp typically -50 deg. C, min. air dewpoint required: -100)
- FTS-40 preconditioning unit: -40...+100 deg. C air chiller/heater (min. sample temp typically -20 deg. C, min. air dewpoint required: -60)
- 50 l nitrogen dewar with heat exchanger: for long-time low-temperature work (needs nitrogen gas supply)
- Bruker BCU-05: -20 deg. C air chiller (min. sample temp typically -5...-15 deg. C, min. air dewpoint required: -40)
- Bruker nitrogen gas generator: for long-time low-temperature work (needs small nitrogen dewar, BVT to control)
Upgrades
- Older DRX to AV1 upgrade: Complete console upgrade including all required parts and installation (keep your magnet, much of the console and probes). Supports max. Topspin 2.1 (Windows XP/Centos 6/7), computer on request.
- Older DRX or AV1 to AV2 upgrade: Complete console upgrade including all required parts and installation (keep your magnet, most of console and probes). Supports max. Topspin 3.2 (Windows 10/Centos 6/7), computer on request.
- AV1 Receiver upgrade: Replace standard SADC (100 kHz max. spectral width) with HADC digitizer (max. 1 MHz spectral width)
Spare parts/Accessories
- Avance AQS/AQS2 boards: SGU400, RX22, SADC, HADC/2, REF22, REF400-22, Router3/5, CCU11, CCU10, CCU8, GCU, FCU4/4, FCU3, TCU3/4, RCU1/2, ACB-X
- Avance AQR boards: ASU1, ASU2, LOT, ACB
- Avance BSMS boards: CPU/3, CPU/2, LCB, SLCB, SLCB/2, L-TX200/300/400/600, L-RX200/300/400/600, 2H-TX200-400, 2H-TX500-900
- Avance shim boards: SCB7M-16bit, SCB13R-16bit, SCB13L-16S, SCB13M-16S, SCB13R-2OU br>
- Avance preamps: Diverse HPPR, HPPR/2
- Avance gradient amplifiers: GAB board, GREAT 1/10
- Temperature controllers: BVT3000, BVT3200 (board)
- MAS controllers: MAS1, MAS2
- PTS frequency synthesizers: DL620V002SX-88
- Diverse Power supplies, cables etc.
- RF filters for liquids and solids NMR (or other uses). A large variety of frequencies is available, bandpass, high- or lowpass and notch filters, low-power versions for liquids NMR as well as high-power (kW) for solids.
- Sample spinners: 5 mm (room-temperature only)
Ask for a quotation
Your used systems/parts
Do you have any used NMR system(s) or spares you no longer need and want to get rid of?
Please contact me!
Updated 1 May 2023
|
|